RoiGroup and Roi API
Roi Hierarchy
ScanImage® organizes Rois and Scanfields in a hierarchy. The root of this hiearchy is a RoiGroup object. Each RoiGroup object can contain multiple Rois, and each Roi can contain multiple scanfields.
- RoiGroup
- Roi
Scanfield, z = 0
Scanfield, z = 0.2
Scanfield, z = 0.3
- Roi
Scanfield, z = 0.1
Scanfield, z = 0.5
- Roi
Scanfield, z = 0.4
Scanfield, z = 1
RoiGroup
A RoiGroup is a container that holds multiple Rois. There are multiple accessor methods to manipulate the Rois within a RoiGroup. The order of the Rois within the RoiGroup determines the order the Rois that are scanned on one slice.
Note
RoiGroup, Roi, and Scanfield hare handle object. The same Roi can be added to a RoiGroup multiple times, or be used in different RoiGroups. The same Scanfield can be added to different Rois, or multiple times to a single Roi.
Create a RoiGroup and add Rois
hRoiGroup = scanimage.mroi.RoiGroup(); % create an empty RoiGroup object
hRoi1 = scanimage.mroi.Roi(); % create an empty Roi
hRoiGroup.add(hRoi1); % add hRoi1 to hRoiGroup
hRoi2 = scanimage.mroi.Roi(); % create an empty Roi
hRoiGroup.add(hRoi2); % add hRoi2 to hRoiGroup
hRoiGroup.clear(); % removes all Rois from RoiGroup
Manipulate RoiGroup
% insert Roi at defined position
hRoi0 = scanimage.mroi.Roi(); % create an empty Roi
hRoiGroup.insertAfterId(0,hRoi0); % add hRoi0 to beginning of hRoiGroup
% reorder Roi list
newIdx = hRoiGroup.moveById(2,1); % move second Roi one step towards end
newIdx = hRoiGroup.moveById(2,-1); % move second Roi one step towards front
newIdx = hRoiGroup.moveToFrontById(2); % move second Roi to front
newIdx = hRoiGroup.moveToBackById(2); % move second Roi to back
hRoi = hRoiGroup.removeById(2); % removes second Roi from hRoiGroup
Note
Each Roi, RoiGroup and Scanfield object has a unique identifier ‘uuid’, which is a human readable string. For performance reasons, a 64-bit integer value ‘uuiduint64’ is derived from ‘uuid’, which can be used to identify the object in the RoiGroup.
Manipulate RoiGroup using uuiduint64
hMyRoi = scanimage.mroi.Roi(); % create an empty Roi
myRoi_uuid = hMyRoi.uuid; % get unique identifier (human readble string)
disp(hMyRoi.uuid); % display human readable unique identifier
myRoi_uuiduint64 = hMyRoi.uuiduint64; % get unique identifier (uint64)
uuiduint64s = [hRoiGroup.rois.uuiduint64]; % get uuiduint64s for all Rois in hRoiGroup
hRoiGroup.insertAfterId(uuiduint64s(2),hMyRoi);
% manipulate RoiGroup using uuid - this is slow!!!
newIdx = hRoiGroup.moveById(myRoi_uuid,1); % this works, but is slow; use uuiduint64 instead for better performance!
% manipulate RoiGroup using uuiduint64
newIdx = hRoiGroup.moveById(myRoi_uuiduint64,1) % move hMyRoi one step towards end
newIdx = hRoiGroup.moveById(myRoi_uuiduint64,-1) % move hMyRoi one step towards front
newIdx = hRoiGroup.moveToFrontById(myRoi_uuiduint64) % move hMyRoi to front
newIdx = hRoiGroup.moveToBackById(myRoi_uuiduint64) % move hMyRoi to back
idx = hRoiGroup.idToIndex(roi_uuiduint64); % find hMyRoi in hRoiGroup
hMyRoi = hRoiGroup(idx); % get hMyRoi from hRoiGroup
hMyRoi = hRoiGroup.removeById(roi_uuiduint64); % removes hMyRoi from hRoiGroup
Roi
Manipulate Rois
hSf0 = scanimage.mroi.scanfield.fields.RotatedRectangle(); % create an imaging Scanfield
hSf1 = scanimage.mroi.scanfield.fields.RotatedRectangle(); % create an imaging Scanfield
hSf2 = scanimage.mroi.scanfield.fields.RotatedRectangle(); % create an imaging Scanfield
hRoi = scanimage.mroi.Roi(); % create an empty Roi
hRoi.add(0,hSf0); % add Scanfield at z = 0
hRoi.add(1,hSf1); % add Scanfield at z = 1
hRoi.add(2,hSf2); % add Scanfield at z = 2
hSf.scanfields % show lists of Scanfields in roi
hSf.zs % show list of zs
tf = hSf.hit(3) % check if Roi is defined at z=3
tf = hSf.hit(0.5) % check if Roi is defined at z=0.5
hSf_interpolated = hRoi.get(0.5); % return interpolated Scanfield at z=0.5
idx = hRoi.idToIndex(hSf0.uuiduint64); % find Scanfield with given uuid in Roi
hRoi.removeById(idx); % remove Scanfield from Roi
hRoi.removeByZ(2); % remove Scanfield at z=2 from Roi
Scanfields
Each Roi can contain one or more Scanfields. A Scanfield is a 2D cross-section of the 3D Roi at a particular z level. ScanImage® currently supports multiple types of scanfields.
RotatedRectangle API - defines an imaging area
StimulusField API - defines a stimulus path
IntegrationField API - defines a region, where image data is integrated for online analysis
All fields are defined in the ScanImage® Coordinate Systems coordinate system.